Overview
Real Time Results
The ProFoss™ 2 in-line analyser delivers accurate, real-time measurements for a range of food and agri process applications. Exploiting the latest developments in NIR process technology, ProFoss 2 makes it simple for you to share in the power of in-line process control. Real time measurements allow for standardizing critical control parameters for improved yield and profit while always meeting quality and legislative requirements. Having our solution placed directly in-line removes the risk of sample preparation error. The ProFoss™ 2 is equipped with advanced software and connectivity features to provide Just in Time reports while maintaining uptime through automated system and calibration monitoring.
Parameters
Sample Type
Technology
Performance validation
![Performance1200x500](https://www.haes.co.id/haes_5.1/wp-content/uploads/2022/06/Performance1200x500.jpg)
Registering and measuring samples by the ProFoss 2 and a bench top analyser (FoodScan 2 or NIRS DS3) reduces the risk of error and secure optimal performance. Using integration, connectivity and automation the results matched are saved via cloud and are ready for evaluation and reporting using digital services
Trend Analysis
![TrendAnalysis1200x500](https://www.haes.co.id/haes_5.1/wp-content/uploads/2022/06/TrendAnalysis1200x500.jpg)
ProFoss™ 2 allows you to do direct measurements in the process line, thereby effectively avoiding sampling errors and sample preparation errors. The results are shown in an intuitive graphical display, making it easy to spot variations. Because ProFoss™ 2 is measuring every few seconds it gives a reliable picture of what is going on in the process.
High resolution near infrared technology
![HighResolution1200x500](https://www.haes.co.id/haes_5.1/wp-content/uploads/2022/06/HighResolution1200x500.jpg)
High resolution diode array technology ensures accurate and continuous analysis, giving you a clearer picture of your process. A high number of pixels (diode sensors) in the spectrum secures a more detailed (accurate) and uniform (repeatable) analysis result
Performance Data
Measurement mode | Reflectance |
Analysis Frequency | Real time: Average analysis time per result 2 – 3 seconds |
Wavelength range | 1100 – 1650 nm |
Detector | InGaAs Diode Array |
Spectral dispersion | 1.1 nm / pixel |
General | |
Technology | NIR Technology |
Software package | ISIscan™ NOVA for instrument control |
Wavelength accuracy | <0.5 nm |
Wavelength precision | < 0.02 nm |
Wavelength stability | < 0.01 nm/°C |
Noise | < 60 micro AU |
IP69 is the highest protection for dust entering the unit. IP69 means protected against the effect of high-pressure water and/or steam cleaning high temperature |